Introduction
DDC-JQ electro-vacuum charging valve is a safety valve for vacuum pump. It is mounted at the intake nozzle of vacuum pump. In case that vacuum pump stops working or power supply is suddenly broken off, valve will be closed automatically to maintain the vacuum constant and inject air into the pump chamber, thus to prevent the pollution of vacuum system due to reverse flow of oil. Applicable medium can be pure air and noncorrosive gases.
Specification
Applicability | 105~10-3Pa |
Valve Leak Rate | ≤6.7×10-3 Pa.L/s |
Applicable Temperature | -30~+50℃ |
Coil Temperature Rise | ≤65℃ |
Open-Close Time | ≤3s |
Mains Voltage | 220v/50Hz |
Power | 15w~40w |
Frequency | ≤3 times/min |
Peak Current | 0.2A(DN25~DN40), 2A(DN50~DN80) |
Power Dissipation | 12w,40w(DN25~DN40), ≤12w(DN50~DN80) |
Installation Direction | Vertical or Horizontal |
Materials of Main Parts
Body, bonnet and disc:carbon steel and aluminum alloy
Seal ring:NBR
Overall and Connection Dimensions (mm) (JB919)
Model | DN | h | B | H | D | Do | D1 | n-d | Mechanical pump |
DDC-JQ16 | 16 | 28 | 48 | 176 | 68 | 42 | 22 | 4-M5 | 2XZ-0.5~1 |
DDC-JQ25 | 25 | 35 | 58 | 199 | 82 | 55 | 29 | 4-M6 | 2XZ-2~4 |
DDC-JQ32 | 32 | 40 | 68 | 222 | 92 | 64 | 36 | 4-M6 | 2XZ-4 |
DDC-JQ40 | 40 | 44 | 80 | 253 | 110 | 70 | 44 | 4-M6 | 2XZ-8 |
DDC-JQ50 | 50 | 56 | 94 | 294 | 124 | 90 | 55 | 4-M8 | 2X-15 |
DDC-JQ65 | 65 | 65 | 115 | 320 | 135 | 105 | 70 | 4-M8 | 2X-30 |
DDC-JQ80 | 80 | 75 | 140 | 367 | 165 | 125 | 85 | 4-M8 | 2X-70 |